Dwyer Differential Pressure Gauge 0 to 250 mm
Dwyer Differential Pressure Gauge 0 to 250 mm

Dwyer Differential Pressure Gauge 0 to 250 mm

MOQ : 1 Piece

Dwyer Differential Pressure Gauge 0 to 250 mm Specification

  • Product Type
  • Pressure Gauge
  • Material
  • Metal
  • Usage
  • Display Pressure Difference, Between Two Pressure
  • Accuracy
  • 2 %
  • Weight
  • 510-963 Grams (g)
 

Dwyer Differential Pressure Gauge 0 to 250 mm Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID), Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Days
  • Main Domestic Market
  • All India
 

About Dwyer Differential Pressure Gauge 0 to 250 mm

Dwyer Magnehelic Differential Pressure Gages,Range: 0-250 mmWC

Service:

Air and non-combustible, compatible gases (natural gas option available). Note: May be used with hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi

Wetted Materials:

Consult factor

Housing:

Die cast aluminum case and bezel, with acrylic cover. Exterior finish is coated gray to withstand 168 hour salt spray corrosion test

Accuracy:

±2% of FS (±3% on - 0, -100 Pa, -125 Pa, 10MM and ±4% on - 00, -60 Pa, -6MM ranges), throughout range at 70°F (21.1°C )

Pressure Limits:

-20 in Hg to 15 psig (-0.677 to 1.034 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).

Overpressure:

Relief plug opens at approximately 25 psig (1.72 bar), standard gages only. See Overpressure Protection Note on next page

Temperature Limits:

20 to 140°F* (-6.67 to 60°C). -20°F (-28°C) with low temperature option

Size:

4 (101.6 mm) diameter dial face

Mounting Orientation:

Diaphragm in vertical position. Consult factory for other position orientations Standard Accessories: Two 1/8 NPT plugs for duplicate pressure taps, two 1/8 pipe thread to rubber tubing adapter, and three flush mounting adapters with screws. (Mounting and snap ring retainer substituted for three adapters in MP & HP gage accessories.)

 



Reliable Differential Pressure Measurement

Designed for clarity and accuracy, this gauge ensures reliable measurement of differential pressure ranging from 0 to 250 mm, with a tight accuracy margin of 2%. Its durable metal construction offers long-term performance in demanding environments, making it suitable for various industrial and laboratory uses.


Versatile Applications

The Dwyer Differential Pressure Gauge is ideal for monitoring air and gas pressures in systems like HVAC, filtration, and clean rooms. Its application versatility extends to quality assurance and process monitoring tasks where accurate pressure differential is crucial for safety and efficiency.

FAQ's of Dwyer Differential Pressure Gauge 0 to 250 mm:


Q: How does the Dwyer Differential Pressure Gauge measure pressure difference?

A: This gauge measures and displays the difference between two separate pressure sources by connecting one to each side of the device. It gives a direct reading on the scale marked from 0 to 250 mm, indicating the precise pressure differential.

Q: What materials are used in the construction of the gauge and what is its weight range?

A: The Dwyer Differential Pressure Gauge is manufactured with sturdy metal components, ensuring durability and longevity. Its weight varies between 510 grams and 963 grams, dependent on model and configuration.

Q: When should I use a differential pressure gauge in my system?

A: You should use a differential pressure gauge when it's important to monitor the difference in pressure across two points, such as in filters, clean rooms, or ventilation systems, to assure system integrity and optimal performance.

Q: Where can I buy or source the Dwyer Differential Pressure Gauge in India?

A: These gauges are readily available through authorized distributors, exporters, manufacturers, suppliers, and traders across India. You can contact local industrial equipment providers for availability and pricing.

Q: What is the benefit of using a differential pressure gauge with 2% accuracy?

A: A 2% accuracy rating means that the measured value is highly reliable, reducing the risk of error and ensuring precise monitoring. This level of accuracy helps protect sensitive processes and maintains safety standards.

Q: How do I install and use the differential pressure gauge?

A: Installation typically involves connecting the gauge to the two pressure points in your system using compatible fittings. Once installed, the gauge will continuously monitor and display the pressure difference, aiding operational decision-making.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Dwyer HVAC Sensors Category

Wall Mount Humidity Transmitter

Wall Mount Humidity Transmitter

Price 6500 INR / Piece

Minimum Order Quantity : 1 , , Piece

Usage : Indoor Environment Monitoring

Accuracy : 2% RH (Humidity), 0.3C (Temperature)

Product Type : Humidity Transmitters

Wall Mount Humidity/TemperatureTransmitter

Wall Mount Humidity/TemperatureTransmitter

Price 6500 INR / Piece

Minimum Order Quantity : 1 , , Piece

Usage : Indoor environmental monitoring

Accuracy : 2% RH, 0.3C

Product Type : Humidity Transmitter

Duct Mount Humidity/Temperature Transmitter

Duct Mount Humidity/Temperature Transmitter

Price 1100 INR / Piece

Minimum Order Quantity : 1 , , Piece

Usage : HVAC, Building Automation

Accuracy : 2% RH, 0.5C

Product Type : Temperature Transmitter

Dwyer Differential Pressure Gauge 0 to 500 Pa

Dwyer Differential Pressure Gauge 0 to 500 Pa

Price Range 5000.00 - 7700.00 INR

Minimum Order Quantity : 1 Piece

Usage : Display Pressure Difference, Between Two Pressure

Accuracy : 2 %

Product Type : Pressure Gauge